Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BackgroundGlucose-6-phosphate dehydrogenase (G6PD) deficiency is the main risk factor for severe haemolysis following treatment with 8-aminoquinolines (8AQ). The World Health Organization recommends G6PD testing prior to 8AQ-based hypnozoitocidal treatment.MethodsWe undertook an individual level meta-analysis of the performance of commercially available quantitative point-of-care diagnostics (PoCs) compared with reference spectrophotometry. A systematic literature search (PROSPERO: CRD42022330733) identified 595 articles of which 16 (2.7%) fulfilled pre-defined inclusion criteria and were included in the analysis, plus an additional 4 datasets. In total there were 12,678 paired measurements analyzed, 10,446 (82.4%) by STANDARD G6PD Test (SD Biosensor, RoK, [SDB]), 2,042 (16.1%) by CareStart G6PD Biosensor (AccessBio, USA, [CSA]), 150 (1.2%) by CareStart Biosensor (WellsBio, RoK [CSW]), and 40 (0.3%) by FINDER (Baebies, USA, [FBA]).FindingsThe pooled sensitivities of the SDB when measuring G6PD activity <30% of normal were 0.82 (95% confidence interval [CI]: 0.72-0.89) for capillary and 0.93 (95% CI: 0.75-0.99) for venous blood samples. The corresponding values for measuring <70% G6PD activity were 0.93 (95% CI: 0.67-0.99) and 0.89 (95% CI: 0.73-0.96), respectively. The pooled specificity of the SDB was high (>96%) for all blood samples and G6PD activity thresholds. Irrespective of the blood samples and thresholds applied, sensitivity of the CSA did not exceed 62%, although specificity remained high at both 30% and 70% thresholds (>88%). Only one study each for CSW and FBA was included. Sensitivities of the CSW were 0.04 (95% CI: 0.01-0.14) and 0.81 (95% CI: 0.71-0.89) at the 30% and 70% thresholds, respectively (venous blood samples). Sensitivities of the FBA were 1.00 (95% CI: 0.29-1.00) and 0.75 (95% CI: 0.19-0.99) at the 30% and 70% thresholds (venous blood samples). Specificities of the CSW and FBA were consistently high (>90%) at both thresholds. Accuracy of the SDB was higher in females at the 30% cut-off (OR: 3.49, p=0.002) and lower in malaria patients at the 70% cut-off (OR: 0.59, p = 0.005).ConclusionsThe SDB performed better than other PoCs. More evidence was available for the performance of the SDB compared to other PoCs, giving higher confidence in its utility in diagnosing G6PD deficiency.

Original publication

DOI

10.1371/journal.pntd.0012864

Type

Journal

PLoS neglected tropical diseases

Publication Date

03/2025

Volume

19

Addresses

Menzies School of Health Research and Charles Darwin University, Global and Tropical Health Division, Darwin, Australia.

Keywords

Humans, Glucosephosphate Dehydrogenase Deficiency, Aminoquinolines, Glucosephosphate Dehydrogenase, Sensitivity and Specificity, Adolescent, Adult, Point-of-Care Systems, Female, Male, Young Adult, Point-of-Care Testing